THERMOSTAT > INSPECTION |
| 1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY |
![]() |
Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
Check the valve opening temperature of the water inlet with thermostat sub-assembly.
![]() |
Check the valve lift.
| *a | 10 to 14 mm |
Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).