COOLANT (for Inverter) > ON-VEHICLE INSPECTION |
| 1. INSPECT FOR COOLANT LEAK (for Inverter) |
Remove the reserve tank cap.
![]() |
Install a radiator cap tester.
Pump the radiator cap tester to 122 kPa (1.2 kgf/ cm2, 18 psi), and then check that the pressure does not drop.
Reinstall the reserve tank cap.
| 2. INSPECT COOLANT LEVEL IN RESERVE TANK (for Inverter) |
The coolant should be between the L and F lines when the coolant for the inverter is cold.
| 3. INSPECT COOLANT (for Inverter) |
Remove the reserve tank cap.
Check for excessive deposits of rust or scale on and around the reserve tank cap and its opening.
Reinstall the reserve tank cap.
| 4. INSPECT RESERVE TANK CAP (for Inverter) |
![]() |
Inspect the reserve tank cap.
| *1 | O-ring |
| *2 | Rubber Packing |
If there are water stains or foreign matter on the O-ring, clean it with water and finger scouring.
Check that the O-ring is not deformed, cracked, or damaged.
Check that the O-ring is not swollen.
![]() |
Check the reserve tank cap operation.
| *1 | Radiator Cap Tester |
| *2 | Reserve Tank Cap |
| *a | 30° or more |
Apply coolant (for inverter) to the O-ring and rubber packing before using a radiator cap tester.
Install the reserve tank cap to the radiator cap tester.
Pump the cap tester several times, and check the maximum pressure.
| Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum standard value (for used cap) | 94 kPa (1.0 kgf/cm2, 13.6 psi) |
| Pump speed | 1 pump per second |