HEADLIGHT RELAY > INSPECTION
for Preparation
Click here
1. INSPECT HEADLIGHT RELAY (Marking: HEAD LP)
Measure the resistance of the relay.
Standard resistance:
Tester Connection
Specified Condition
3 - 5
10 kΩ or higher
3 - 5
Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
If the result is not as specified, replace the relay.