AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
![]() |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Read the Data List according to the display on the tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Room Temperature Sensor (Room Temp) | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (126.95°F) | Actual room temperature is displayed | - |
| Ambient Temp Sensor (Ambi Temp Sens) | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | - |
| Evaporator Temp Sensor (Evap Temp) | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | - |
| Solar Sensor (D side) (Solar Sens - D) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side temperature increases as brightness increases | - |
| Solar Sensor (P side) (Solar Sens - P) | Passenger side solar sensor / Min.: 0, Max.: 255 | Passenger side temperature increases as brightness increases | - |
| Engine Coolant Temp (Coolant Temp) | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed while engine is warmed up | - |
| Set Temperature (D Side) (Set Temp - D) | Driver side set temperature / Min.: 0, Max.: 255 | Driver side actual set temperature is displayed | - |
| Set Temperature (P Side) (Set Temp - P) | Passenger side set temperature / Min.: 0, Max.: 255 | Passenger side actual set temperature is displayed | - |
| Estimated Temp (D Side) (Estimate Temp - D) | Driver side estimated temperature / Min.: -358.4°C (-613.12°F) Max.: 358.4°C (677.12°F) | Driver side actual estimated temperature is displayed | - |
| Estimated Temp (P Side) (Estimate Temp - P) | Passenger side estimated temperature / Min.: -358.4°C (-613.12°F) Max.: 358.4°C (677.12°F) | Passenger side actual estimated temperature is displayed | - |
| Hand Free Telephone (Hand Free Tel) | Hands free telephone / OFF or ON | - | - |
| Blower Motor Speed Level (Blower Level) | Blower motor speed level / Min.: 0 level, Max.: 31 level | Increases in the range between 0 and 31 as the blower motor speed increases | - |
| Adjusted Ambient Temp (Ambi Temp) | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | - | - |
| Emission Gas Sensor (Emiss Gas Sens) | Emission gas / Min.: 0 V, Max.: 255 V | Increases as the gas amount increases | - |
| Shift Set Temperature (Set Temp Shift) | Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C | Customized value will be displayed | - |
| Air Inlet Mode (Air Inlet Mode) | Air inlet mode / AUTO, MANUAL | Customized value will be displayed | - |
| Compressor Mode (Compressor Mode) | Compressor mode / AUTO, MANUAL | Customized value will be displayed | - |
| Compressor / DEF Mode (Comprs / DEF Oper) | Compressor / DEF mode / LINK, NORMAL | Customized value will be displayed | - |
| Evaporator Control (Evap Ctrl) | Evaporator control / AUTO, MANUAL | Customized value will be displayed | - |
| Emission Gas Sensor Shift (Gas Sens Shift) | Emission gas sensor shift / MU MORE, MORE, LI MORE, NORMAL, LI LESS, LESS, MU LESS | Customized value will be displayed | - |
| Button Press Buzzer (Button Prs Buz) | Button press buzzer / ON, OFF | Customized value will be displayed | - |
| Foot Air Leak (Foot Air Leak) | Foot air leak / ON, OFF | Customized value will be displayed | - |
| Foot / DEF Auto Blow Up (Auto Blow Up) | Foot / DEF auto blower up function / ON, OFF | Customized value will be displayed | - |
| Foot / DEF Auto Mode (Foot / DEF Mode) | Foot / DEF auto mode / ON, OFF | Customized value will be displayed | - |
| Ambient Temperature Shift (Ambient Tmp Sft) | Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C | Customized value will be displayed | - |
| Destination (Destination) | Destination / DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO | Changes value with destinations | - |
| Emission Gas Nox Sensor (Nox Gas Sens) | Emission gas / Min.: 0, Max.: 255 | Increases as gas amount increases | - |
| Regulator Pressure Sensor (Reg Press Sens) | Regulator pressure sensor / Min.: 0, Max.: 255 | Actual regulator pressure is displayed | - |
| Regulator Control Current (Reg Ctrl Current) | Regulator control current / Min.: 0 A, Max.: 255 A | - | - |
| Humidity Sensor (Humidity Sens) | Humidity sensor / Min.: 0%, Max.: 100% | Actual room humidity is displayed | - |
| Air Mix Servo Targ Pulse (D) (Air Mix Pulse - D) | Driver side air mix servomotor target pulse / Min.: 0, Max.: 255 | Customized value will be displayed | - |
| Air Mix Servo Targ Pulse (P) (Air Mix Pulse - P) | Passenger side air mix servomotor target pulse / Min.: 0, Max.: 255 | Customized value will be displayed | - |
| Air Outlet Servo Pulse (D) (Air Out Pulse - D) | Driver side air outlet servomotor target pulse / Min.: 0, Max.: 255 | Customized value will be displayed | - |
| Air Inlet Damper Targ Pulse (A/I Damp Targ Pls) | Air inlet damper target pulse / Min.: 0, Max.: 255 | Customized value will be displayed | - |
| Cool Air Bypass Pulse (A/B Damp Pls) | Driver side cool air bypass pulse / Min.: 0, Max.: 255 | Customized value will be displayed | - |
| Number of Trouble Codes (#Codes) | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs will be displayed | - |
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| A/C signal (A/C Signal) | A/C signal / ON or OFF | ON: A/C ON OFF: A/C OFF | - |
| A/C Magnetic Clutch Relay (A/C Magnetic Clutch Relay) | A/C magnetic clutch relay / OFF, ON | ON: A/C magnetic clutch ON OFF: A/C magnetic clutch OFF | - |
| PERFORM ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Perform the Active Test according to the display on the tester.
| Item | Test Details / Display (Range) | Diagnostic Note |
| Blower Motor (Blower Motor) | Blower motor / Min.: Level 0, Max.: Level 31 | - |
| Magnetic Clutch Relay (A/C Mag Clutch) | Magnetic clutch relay / OFF, ON | - |
| Defogger Relay (Rear) (Defogger Rly - R) | Defogger relay (Rear) / OFF, ON | - |
| Deicer Relay (Front) (Deicer Rly - F) | Deicer relay (Front) / OFF, ON | - |
| Electric Heater 1 (Heater 1) | Electric Heater 1 / OFF, ON | - |
| Electric Heater 2 (Heater 2) | Electric Heater 2 / OFF, ON | - |
| Air Mix Servo Targ Pulse (D) (Air Mix Pulse - D) | Driver side air mix servomotor pulse / Min.: 0, Max.: 255 | - |
| Air Mix Servo Targ Pulse (P) (Air Mix Pulse - P) | Passenger side air mix servomotor pulse / Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) (Air Out Pulse - D) | Driver side air outlet servomotor pulse / Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse (A/I Damp Targ Pls) | Air inlet damper target pulse / Min.: 0, Max.: 255 | - |
| Cool Air Bypass Pulse (A/B Damp Pls) | Cool air bypass pulse / Min.: 0, Max.: 255 | - |