HEATED OXYGEN SENSOR (for Sensor 2) > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR
  1. Disconnect the sensor connector.



    A104021E01
  1. Measure the heater resistance between terminals 1 (HT) and 2 (+B) of the sensor.

    Standard resistance:
    5 to 10 Ω at 20°C (68°F)

    If the result is not as specified, replace the sensor.