CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    A093602E02
  1. Measure the resistance between the terminals.

    Standard resistance:
    6.9 to 7.9 Ω at 20°C (68°F)

    If the result is not as specified, replace the oil control valve.



    A099422E01
  1. Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

    OK:
    Condition
    Specified Condition
    Battery positive (+) voltage is applied
    Valve moves in left arrow direction shown in illustration
    Battery positive (+) voltage is cut off
    Valve moves in right arrow direction shown in illustration

    If the result is not as specified, replace the oil control valve.

    NOTICE:
    If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be output.