HEATED OXYGEN SENSOR (for Sensor 1) > INSTALLATION

for Preparation Click here



1. INSTALL HEATED OXYGEN SENSOR (for Bank 1)


    A100670E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST

  1. Connect the sensor connector.



    A100605
  1. Install the heat insulator with the 2 bolts.

    Torque:
    18 N*m{ 184 kgf*cm , 13 ft.*lbf }



2. INSTALL HEATED OXYGEN SENSOR (for Bank 2)


    A100611E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf } for use with SST
    44 N*m{ 449 kgf*cm , 32 ft.*lbf } for use without SST



    A101954
  1. Install the sensor wire to the 2 wire clamps.

  1. Connect the connector.



3. INSTALL ENGINE UNDER COVER


4. INSTALL NO. 2 ENGINE UNDER COVER


5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


6. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.