HEATED OXYGEN SENSOR (for Sensor 2) > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A062067E01
  1. Disconnect the sensor connector.

  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT) - 2 (+B)
    20°C (68°F)
    10 to 16 Ω
    1 (HT) - 4 (+B)
    20°C (68°F)
    10 kΩ or higher

    If the result is not as specified, replace the sensor.