METER / GAUGE SYSTEM > Malfunction in Odo / Trip Switch

for Preparation Click here


WIRING DIAGRAM


E108034E05


INSPECTION PROCEDURE

1.CHECK MULTIPLEX COMMUNICATION SYSTEM
Please follow these procedures (Click here).
If the multiplex communication system is operating normally, proceed to the next step.

Next


2.READ VALUE OF INTELLIGENT TESTER
  1. Operate the intelligent tester according to the display and select the "Data List".

    Integration control and panel assembly:

    Item
    Measurement Item / Range (Display)
    Normal Condition
    Diagnostic Note
    ODO/TRIP Change SW
    ODO/TRIP switch/ ON or OFF
    ON: Switch is pushed
    OFF: Switch is not pushed
    -
    Trip Reset SW
    TRIP RESET switch/ ON or OFF
    ON: Switch is pushed
    OFF: Switch is not pushed
    -

    OK:
    Switch condition (ON/OFF) can be switched by actual operation.



NG
REPLACE INTEGRATION CONTROL AND PANEL ASSEMBLY
OK

REPLACE COMBINATION METER