METER / GAUGE SYSTEM > FAIL-SAFE CHART |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Water temperature data is interrupted for 5 seconds | Gauge needle indicates below "C" | Water temperature data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While engine switch is in on (IG) position, fuel injection signal is interrupted for 60 seconds | Fuel gauge calibration is performed using average fuel consumption data | Engine switch is turned from off to on (IG) and normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| While engine switch is in the on (IG) position, sender signal is interrupted for 60 seconds and malfunction signal is received from one of gauges for 10 to 20 seconds | Needle indicates "E", and warning light comes on | Engine switch is turned from off to on (IG) and normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| "P to D" data is interrupted for 3 seconds | All indicators go off | Normal data is received |
| "S" data is interrupted for 3 seconds | "S" indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Gear position data is interrupted for 3 seconds or malfunction signal is received | Indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| ABS and brake data is interrupted for 10 seconds | Warning light comes on | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted | Data received most recently remains displayed | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted | Data received most recently remains displayed | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Regular data is interrupted for 10 seconds or more | Indicator goes off | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Airbag data is interrupted for 10 seconds or there is malfunction in the meter's internal CPU | Warning light comes on | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Abnormal data and sensor malfunctioning data are received | "--°F" is displayed | Normal data is received |
| Outside temperature data is interrupted for 10 seconds | "E" is displayed | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Cruise information data is interrupted for 60 seconds | Display becomes blank (only measurement units are displayed) | Normal data is received |
| Condition | Fail-safe Operation | Fail-safe Deactivation Condition |
| Rheostat data is interrupted for 10 seconds or abnormal data is received | Display remains in daytime mode | Normal data is received |