INTEGRATION RELAY > INSPECTION

for Preparation Click here



1. INSPECT INTEGRATION RELAY



A107649E03



    A106666E05
  1. Measure the resistance of the C/OPN relay.

    1. Connect the positive (+) lead from the battery to terminal 2A-8 and negative (-) lead to terminal 2B-3. Using an ohmmeter, check the resistance between the terminals when battery voltage is applied between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      2C-2 - 2B-7
      Below 1 Ω
      2C-1 - 2B-8
      10 kΩ or higher

    2. Connect the positive (+) lead from the battery to terminals 2A-8 and 2C-1, and negative (-) lead to terminal 2B-3 and 2B-7. Using an ohmmeter, check that there is resistance between terminals 2C-1 and 2B-8 when battery voltage is applied between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      2C-1 - 2B-8
      Below 1 Ω
      (when battery voltage is applied to terminals 2A-8 and 2B-3, and 2C-1 and 2B-7)



    A106667E03
  1. Measure the resistance of the EFI MAIN relay.

    1. Disconnect the EFI fuse. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      2A-6 - 2A-7
      Below 1 Ω
      EFI fuse terminal 2 - 2A-8
      10 kΩ or higher

    2. Connect the positive (+) lead from the battery to terminal 2A-6 and negative (-) lead to terminal 2A-7. Using an ohmmeter, check that there is resistance between EFI fuse terminal 2 and terminal 2A-8 when battery voltage is applied between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      EFI fuse terminal 2 - terminal 2A-8
      Below 1 Ω
      (when battery voltage is applied to terminals 2A-6 and 2A-7)



    A106666E05
  1. Measure the resistance of the EFI NO. 2 relay.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      2B-3 - 2A-8
      Below 1 Ω
      2B-7 - 2C-1
      10 kΩ or higher

    2. Connect the positive (+) lead from the battery to terminal 2A-8 and negative (-) lead to terminal 2B-3. Using an ohmmeter, check that there is resistance between terminals 2B-7 and 2C-1 when battery voltage is applied between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      2B-7 - 2C-1
      Below 1 Ω
      (when battery voltage is applied to terminals 2B-3 and 2A-8)