POWER SEAT SWITCH > INSPECTION |
| 1. INSPECT FRONT POWER SEAT SWITCH RH |
![]() |
Measure the resistance between the terminals when each switch is operated.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 9 (SLDF) | FRONT | Below 1 Ω |
| 4 (E) - 6 (SLDR) | FRONT | Below 1 Ω |
| 4 (E) - 6 (SLDR) | OFF | Below 1 Ω |
| 4 (E) - 9 (SLDF) | OFF | Below 1 Ω |
| 1 (B) - 6 (SLDR) | REAR | Below 1 Ω |
| 4 (E) - 9 (SLDF) | REAR | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 5 (FUP) | UP | Below 1 Ω |
| 4 (E) - 10 (FDWN) | UP | Below 1 Ω |
| 4 (E) - 5 (FUP) | OFF | Below 1 Ω |
| 4 (E) - 10 (FDWN) | OFF | Below 1 Ω |
| 1 (B) - 5 (FUP) | DOWN | Below 1 Ω |
| 1 (B) - 10 (FDWN) | DOWN | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 8 (LUP) | UP | Below 1 Ω |
| 4 (E) - 7 (LDWN) | UP | Below 1 Ω |
| 4 (E) - 7 (LDWN) | OFF | Below 1 Ω |
| 4 (E) - 8 (LUP) | OFF | Below 1 Ω |
| 1 (B) - 7 (LDWN) | DOWN | Below 1 Ω |
| 4 (E) - 8 (LUP) | DOWN | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 3 (RCLF) | FRONT | Below 1 Ω |
| 2 (RCLR) - 4 (E) | FRONT | Below 1 Ω |
| 2 (RCLR) - 4 (E) | OFF | Below 1 Ω |
| 3 (RCLF) - 4 (E) | OFF | Below 1 Ω |
| 1 (B) - 2 (RCLR) | REAR | Below 1 Ω |
| 3 (RCLF) - 4 (E) | REAR | Below 1 Ω |
| 2. INSPECT FRONT POWER SEAT SWITCH LH |
![]() |
Measure the resistance between the terminals when each switch is operated.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 9 (SLDF) | FRONT | Below 1 Ω |
| 4 (E) - 6 (SLDR) | FRONT | Below 1 Ω |
| 4 (E) - 6 (SLDR) | OFF | Below 1 Ω |
| 4 (E) - 9 (SLDF) | OFF | Below 1 Ω |
| 1 (B) - 6 (SLDR) | REAR | Below 1 Ω |
| 4 (E) - 9 (SLDF) | REAR | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 10 (FUP) | UP | Below 1 Ω |
| 4 (E) - 5 (FDWN) | UP | Below 1 Ω |
| 4 (E) - 10 (FUP) | OFF | Below 1 Ω |
| 4 (E) - 5 (FDWN) | OFF | Below 1 Ω |
| 1 (B) - 10 (FUP) | DOWN | Below 1 Ω |
| 1 (B) - 5 (FDWN) | DOWN | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 7 (LUP) | UP | Below 1 Ω |
| 4 (E) - 8 (LDWN) | UP | Below 1 Ω |
| 4 (E) - 7 (LDWN) | OFF | Below 1 Ω |
| 4 (E) - 7 (LUP) | OFF | Below 1 Ω |
| 1 (B) - 8 (LDWN) | DOWN | Below 1 Ω |
| 4 (E) - 7 (LUP) | DOWN | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 1 (B) - 3 (RCLF) | FRONT | Below 1 Ω |
| 2 (RCLR) - 4 (E) | FRONT | Below 1 Ω |
| 2 (RCLR) - 4 (E) | OFF | Below 1 Ω |
| 3 (RCLF) - 4 (E) | OFF | Below 1 Ω |
| 1 (B) - 2 (RCLR) | REAR | Below 1 Ω |
| 3 (RCLF) - 4 (E) | REAR | Below 1 Ω |