DTC P0710 Transmission Fluid Temperature Sensor "A" Circuit |
DTC P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input |
DTC P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0710 | (a) and (b) are detected momentary within 0.5 sec. when neither P0712 or P0713 is not detected (1-trip detection logic) (a) ATF temperature sensor resistance is less than 79 Ω. (b) ATF temperature sensor resistance is more than 156 kΩ.
|
|
| P0712 | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic) |
|
| P0713 | ATF temperature sensor resistance is more than 156 kΩ when 15 minutes or more after the engine start DTC is detected for 0.5 sec. or more (1-trip detection logic) |
|

| DATA LIST |
Warm up the engine.
Turn the engine switch off.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) position.
Turn on the tester.
Select the item "Enter / Power train / ECT / Data List".
Follow the instructions on the tester and read the Data List.
| Item | Measurement Item/ Range (display) | Normal Condition |
| A/T Oil Temperature 1 | ATF Temp. Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150 °C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 (E2) - 9 (OIL) | 79 Ω to 156 kΩ |
| 1 (E2) - Body ground | 10 kΩ or higher |
| 9 (OIL) - Body ground | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 20 °C (68°F) | 3 to 4 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E7 - 27 (OIL) - E7 - 26 (EOIL) | 79 Ω to 156 kΩ |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E7 - 27 (OIL) - Body ground | 10 kΩ or higher |
| E7 - 26 (EOIL) - Body ground | ↑ |
|
| ||||