DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|

| 1.INSPECT TRANSMISSION WIRE (SLT) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 13 (SLT+) - 5 (SLT-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 13 (SLT+) - Body ground | 10 kΩ or higher |
| 5 (SLT-) - Body ground | ↑ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E7 - 35 (SLT+) - E7 - 34 (SLT-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E7 - 35 (SLT+) - Body ground | 10 kΩ or higher |
| E7 - 34 (SLT-) - Body ground | ↑ |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 1 - 2 | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | ||
| ||