DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

Click here.

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM


C110586E01


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)


    C110342E22
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    13 (SLT+) - 5 (SLT-)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Resistance (Check for short):
    Tester Connection
    Specified Condition
    13 (SLT+) - Body ground
    10 kΩ or higher
    5 (SLT-) - Body ground



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C106186E26
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    E7 - 35 (SLT+) - E7 - 34 (SLT-)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Resistance (Check for short):
    Tester Connection
    Specified Condition
    E7 - 35 (SLT+) - Body ground
    10 kΩ or higher
    E7 - 34 (SLT-) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SLT


    G020767E08
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPAIR OR REPLACE TRANSMISSION WIRE