DTC P0979 Shift Solenoid "C" Control Circuit Low (Shift Solenoid Valve S3) |
DTC P0980 Shift Solenoid "C" Control Circuit High (Shift Solenoid Valve S3) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0979 | ECM detects short in solenoid valve S3 circuit 2 times when solenoid valve S3 is operated (1-trip detection logic) |
|
| P0980 | ECM detects open in solenoid valve S3 circuit 2 times when solenoid valve S3 is operated (1-trip detection logic) |
|

| ECM command gearshift | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve S3 | ON | ON | ON | OFF | OFF | OFF |
| 1.INSPECT TRANSMISSION WIRE (S3) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 7 - Body ground | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transmission.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E7 - 17 (S3) - Body ground | 11 to 15 Ω |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S3 |
![]() |
Remove the shift solenoid valve S3.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| Solenoid Connector (S3) - Solenoid Body (S3) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
|
| ||||
| OK | ||
| ||