DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0778 | The ECM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears. (1-trip detection logic)
|
|

| ECM command gearshift | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve SL2 | ON | ON | ON | ON | OFF | OFF |
| 1.INSPECT TRANSMISSION WIRE (SL2) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 10 (SL2+) - 2 (SL2-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 10 (SL2+) - Body ground | 10 kΩ or higher |
| 2 (SL2-) - Body ground | ↑ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission connector to the transmission.
Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| E7 - 11 (SL2+) - E7 - 10 (SL2-) | 5.0 to 5.6 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E7 - 11 (SL2+) - Body ground | 10 kΩ or higher |
| E7 - 10 (SL2-) - Body ground | ↑ |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition 20°C (68°F) |
| 1 - 2 | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
|
| ||||
| OK | ||
| ||