STARTER CUT RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK STARTER CUT RELAY (Marking: ST CUT)


B060778E14
  1. Measure the resistance of the relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 MΩ or higher
    3 - 5
    Below 1 Ω
    (when battery voltage is applied to terminals 1 and 2)