POWER WINDOW CONTROL SYSTEM > FAIL-SAFE CHART

for Preparation Click here



Description
  1. If a hall IC built-in power window regulator motor or a microcomputer built-in master switch malfunctions, the power window system enters fail-safe mode. In this mode, power window system operates as follows:

    Power window control system 
    Power window function
    Engine switch status
    Power window operation
    Jam protection function
    Manual UP (switch fully pulled up and held)
    Engine switch on (IG)
    Operative
    Operation prohibited
    Manual DOWN
    Engine switch on (IG)
    Operative
    Operation prohibited
    Key-linked open
    -
    Operative*
    -
    Key-linked close
    -
    Operative*
    Operative
    Transmitter-linked open
    -
    Operative*
    -
    Transmitter-linked close
    -
    Operative*
    Operative
    Entry lock switch-linked up
    -
    Operative*
    Operative
    Manual UP (switch fully pulled up and held)
    Engine switch off (key-off function operates)
    Operative
    Operative
    Manual DOWN
    Engine switch off (key-off function operates)
    Operative
    -
    AUTO UP
    Engine switch off (key-off function operates)
    Operative
    Operative
    AUTO DOWN
    Engine switch off (key-off function operates)
    Operative
    Operative
    Remote manual UP (switch fully pulled up and held)
    Engine switch on (IG)
    Operative*
    -
    Remote manual DOWN
    Engine switch on (IG)
    Operative*
    -
    Remote manual UP (switch fully pulled up and held)
    Engine switch off (key-off function operates)
    Operative*
    Operative
    Remote manual DOWN
    Engine switch off (key-off function operates)
    Operative*
    -

    HINT: