DTC B1820/55 Short in Side Squib RH Circuit |
DTC B1821/55 Open in Side Squib RH Circuit |
DTC B1822/55 Short to GND in Side Squib RH Circuit |
DTC B1823/55 Short to B+ in Side Squib RH Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1820/55 |
|
|
| B1821/55 |
|
|
| B1822/55 |
|
|
| B1823/55 |
|
|

| 1.CHECK FRONT SEAT AIRBAG ASSEMBLY RH (SIDE SQUIB RH) |
![]() |
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the front seat airbag assembly RH.
Connect the black wire side of SST (resistance 2.1 Ω) to connector "C".
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the engine switch off.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK FLOOR WIRE (SIDE SQUIB RH CIRCUIT) |
![]() |
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector "C".
Disconnect the connectors from the center airbag sensor assembly.
Check the short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| V3-1 (SFR+) - Body ground | Engine switch on (IG) | Below 1 V |
| V3-2 (SFR-) - Body ground | Engine switch on (IG) | Below 1 V |
Check the open in the circuit.
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| V3-1 (SFR+) - V3-2 (SFR-) | Always | Below 1 Ω |
Check the short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| V3-1 (SFR+) - Body ground | Always | 1 MΩ or higher |
| V3-2 (SFR-) Body ground | Always | 1 MΩ or higher |
Check the short in the circuit.
Release the activation prevention mechanism built into connector "B" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| V3-1 (SFR+) - V3-2 (SFR-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the front seat airbag assembly RH and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the engine switch off.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||