DTC B1835/58 Short in Curtain Shield Squib LH Circuit |
DTC B1836/58 Open in Curtain Shield Squib LH Circuit |
DTC B1837/58 Short to GND in Curtain Shield Squib LH Circuit |
DTC B1838/58 Short to B+ in Curtain Shield Squib LH Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1835/58 |
|
|
| B1836/58 |
|
|
| B1837/58 |
|
|
| B1838/58 |
|
|

| 1.CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH) |
![]() |
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag assembly LH.
Connect the white wire side of SST (resistance 2.1 Ω) to connector "C".
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the engine switch off.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here ).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector "C".
Check that the floor wire No.2 connector (on the curtain shield assembly LH side) is not damaged.
|
| ||||
| OK | |
| 3.CHECK FLOOR WIRE NO.2 (CURTAIN SHIELD SQUIB LH CIRCUIT) |
![]() |
Disconnect the connectors from the center airbag sensor assembly.
Check the short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| W19-1 (ICL+) - Body ground | Engine switch on (IG) | Below 1 V |
| W19-2 (ICL-) - Body ground | Engine switch on (IG) | Below 1 V |
Check the open in the circuit.
Turn the engine switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| W19-1 (ICL+) - W19-2 (ICL-) | Always | Below 1 Ω |
Check the short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| W19-1 (ICL+) - Body ground | Always | 1 MΩ or higher |
| W19-2 (ICL-) Body ground | Always | 1 MΩ or higher |
Check the short in the circuit.
Release the activation prevention mechanism built into connector "B" (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester connection | Condition | Specified condition |
| W19-1 (ICL+) - W19-2 (ICL-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the curtain shield airbag assembly LH and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in memory (Click here).
Turn the engine switch off.
Turn the engine switch on (IG), and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||