VARIABLE GEAR RATIO STEERING SYSTEM > FREEZE FRAME DATA |
| FREEZE FRAME DATA OF STEERING CONTROL ECU |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester on.
Select "FREEZE FRAME DATA" from the display on the tester.
| Intelligent Tester Display | Measurement Item | Value (Unit) |
| Vehicle Speed(Vsc ECU) | Vehicle speed (VSC ECU) | Speed indicated on speedometer (km/h) |
| Engine ReVolution(Rpm) | Engine revolution (rpm) | Less than 300 or more then 300 (rpm) |
| Mtr Power Source Cur. | Motor power source actual current | 0 to 127.5 (A) |
| PIG-Power Source Volt | PIG power source voltage | 0 to 25.5 (V) |
| IG-Power Source Volt | IG power source voltage | 0 to 25.5 (V) |
| Lock Motor Output Volt | LOCK motor output voltage | 0 to 25.5 (V) |
| Command Value Duty | Command value DUTY for PVM control | 0 to 100 (%) |
| Actuator Lock Duty Val | Command value DUTY for actuator lock control | 0 to 100 (%) |
| Resolver Offset (SIN) | Resolver offset (SIN) | 0 to 25.5 (V) |
| Resolver Offset (COS) | Resolver offset (COS) | 0 to 25.5 (V) |
| Motor Current U | Motor current U | -63 to 64.5 (A) |
| Motor Current V | Motor current V | -63 to 64.5 (A) |
| Motor Current W | Motor current W | -63 to 64.5 (A) |
| Motor Voltage | Motor power supply voltage | 0 to 51 (V) |
| Steering Pos1 | Steering position1 | -2047 to 2048.9375 (deg) |
| Actuator Position | Actuator position | -2047 to 2048.9375 (deg) |
| Steering Angle Velocity | Steering wheel angle velocity | -2047 to 2048.9375 (deg/sec) |
| Actuator Target Angle1 | Actuator target angle1 | -2047 to 2048.9375 (deg) |
| Actuator Target Angle2 | Actuator target angle2 | -2047 to 2048.9375 (deg) |
| Actuator ReVolution Spd | Actuator revolution speed | -2047 to 2048.9375 (deg) |