HEIGHT CONTROL SENSOR > INSPECTION |
| 1. REMOVE HEIGHT CONTROL SENSOR SUB-ASSEMBLY FRONT |
![]() |
Connect the 3 dry cell batteries (1.5 V) in series.
Remove the height control sensor.
Connect the battery's positive (+) lead to terminal 1 and the negative (-) lead to terminal 3.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
| Tester Connection | Condition | Specified Condition |
| A20-2 (SHFL) - A20-1 (SHG) | +45° | Approx. 4.5 V |
| A20-2 (SHFL) - A20-1 (SHG) | 0° (normal) | Approx 2.5 V |
| A20-2 (SHFL) - A20-1 (SHG) | -45° | Approx 0.5 V |
| 2. REMOVE HEIGHT CONTROL SENSOR SUB-ASSEMBLY REAR |
![]() |
Connect the 3 dry cell batteries (1.5 V) in series.
Remove the height control sensor.
Connect the battery's positive (+) lead to terminal 1 and the negative (-) lead to terminal 3.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
| Tester Connection | Condition | Specified Condition |
| o20-2 (SHRL) - o20-1 (SHG) | +45° | Approx. 4.5 V |
| o20-2 (SHRL) - o20-1 (SHG) | 0° (normal) | Approx 2.5 V |
| o2-2 (SHRL) - o2-1 (SHG) | -45° | Approx 0.5 V |