AMBIENT TEMPERATURE SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL AMBIENT TEMPERATURE SENSOR


    E108954E01
  1. Install the sensor with the clamp.

  1. Connect the connector.



2. INSTALL FRONT BUMPER COVER
  1. Connect the ultrasonic sensor connector.



    B107496E02
  1. Attach the 3 claws on the LH side.

  1. Attach the 3 claws on the RH side.



    B109982
  1. Install the bumper cover with the 2 clips, 6 screws and 5 bolts.



3. INSTALL COOL AIR INTAKE DUCT SEAL


A105932E01
  1. Install the intake duct seal with the 7 clips.



4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


5. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.