ULTRASONIC SENSOR > INSPECTION |
| 1. INSPECT NO. 1 ULTRASONIC SENSOR |
![]() |
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 (E) - 2 (S) | Always | 900 +- 300 kΩ |
| 2. INSPECT NO. 2 ULTRASONIC SENSOR |
![]() |
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 (E) - 2 (S) | Always | 900 +- 300 kΩ |
| 3. INSPECT NO. 3 ULTRASONIC SENSOR |
![]() |
Measure the resistance of the sensor.
| Tester Connection [Tester (+) - Tester (-)] | Condition | Specified Condition |
| 3 (S) - 2 (E) | Always | 40 +- 10 kΩ |
| 2 (E) - 3 (S) | Always | 40 +- 10 kΩ |
| 1 (T) - 2 (E) * | Always | 330 +- 100 kΩ |
| 2 (E) - 1 (T) * | Always | 1 MΩ or higher |