COOLING FAN MOTOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK NO. 1 COOLING FAN MOTOR


A110241E01
  1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    6.8 to 9.8 A at 20°C (68°F)

    If the result is not as specified, replace the No. 1 cooling fan motor.



2. CHECK NO. 2 COOLING FAN MOTOR


A110242E01
  1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.

  1. Measure the current while the motor is turning.

    Standard current:
    6.8 to 9.8 A at 20°C (68°F)

    If the result is not as specified, replace the No. 2 cooling fan motor.