ABS MOTER RELAY (w/ ECB) > ON-VEHICLE INSPECTION |
| 1. INSPECT ABS MOTOR RELAY |
![]() |
Remove the ABS MOTOR1 relay and ABS MOTOR2 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Always | 10 kΩ or higher (No continuity) |
| 3 - 5 | Apply B+ between terminal 1 and 2 | Below 1 Ω (Continuity) |