3UZ-FE COOLING > SERVICE DATA



No. 1 cooling fan motor
Standard current
2 to 11 A
(when the A/C switch is on (MAX COOL and the magnet clutch is operating))
Standard current
5.6 to 11.6 A at 20°C (68°F)
(when the battery is connected to the fan motor connector)
Standard current
2 to 11 A
(when the water temperature sensor connector is disconnected)
No. 2 cooling fan motor
Standard current
2 to 11 A
(when the A/C switch is on (MAX COOL and the magnet clutch is operating))
Standard current
5.6 to 11.6 A at 20°C (68°F)
(when the battery is connected to the fan motor connector)
Standard current
2 to 11 A
(when the water temperature sensor connector is disconnected)
Water inlet with thermostat
Valve opening temperature
80 to 84°C (176 to 183°F)
Valve lift
8.0 mm (0.315 in.) or more at 95°C (203°F)
Cooling fan relay
Standard resistance: 10 MΩ or higher
Standard resistance: Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
Cooling fan ECU
Standard voltage
9 to 14 V
(when turn the engine switch on (IG))