INSPECTION
Inspection
| INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE S1 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (S1) - Solenoid Body (S1)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE S2 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (S2) - Solenoid Body (S2)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE S3 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (S3) - Solenoid Body (S3)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE S4 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (S4) - Solenoid Body (S4)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SL2 |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SR |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (SR) - Solenoid Body (SR)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.
| INSPECT SHIFT SOLENOID VALVE SLU |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
- OK:
- The solenoid makes an operating sound.