P2759
Diagnostic trouble codes
DESCRIPTION
The amount of current flow to the solenoid is controlled by the (*) duty ratio of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.

(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100(%).
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2759 |
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). |
|
Check the waveform between the terminals SLU+ and SLU- of the ECM connector


- Standard:
- Refer to the illustration.
| Terminal |
SLU+ - SLU- |
| Tool setting |
5 V/DIV., 1 ms./DIV. |
| Vehicle condition |
5th (lock-up) or 6th (lock-up) gear |
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve (SLU) circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store this DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SLU) |
Disconnect the transmission wire connector from the transmission.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
12 (SLU+) - 4 (SLU-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
12 (SLU+) - Body ground
10 kΩ or higher
4 (SLU-) - Body ground
↑
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transmission.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
E4-13 (SLU+) - E4-12 (SLU-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
E4-13 (SLU+) - Body ground
10 kΩ or higher
E4-12 (SLU-) - Body ground
↑
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLU |
Remove the shift solenoid valve SLU.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||