P2716
Diagnostic trouble codes
DESCRIPTION
Refer to DTC P2714 (Click here).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|
Check the waveform between the terminals SLT+ and SLT- of the ECM connector


- Standard:
- Refer to the illustration.
| Terminal |
SLT+ - SLT- |
| Tool setting |
5 V/DIV., 1 ms./DIV. |
| Vehicle condition |
Engine idle speed |
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SLT) |
Disconnect the transmission wire connector from the transmission.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
13 (SLT+) - 5 (SLT-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
13 (SLT+) - Body ground
10 kΩ or higher
5 (SLT-) - Body ground
↑
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transmission.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
E4-35 (SLT+) - E4-34 (SLT-)
5.0 to 5.6 Ω
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for short):
Tester Connection
Specified Condition
E4-35 (SLT+) - Body ground
10 kΩ or higher
E4-34 (SLT-) - Body ground
↑
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
Remove the shift solenoid valve SLT.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||