DATA LIST / ACTIVE TEST
System information
- HINT:
- By accessing the DATA LIST displayed on the intelligent tester, you can perform such functions as reading the values of switches and sensors without removing any parts. Reading the DATA LIST is first step in troubleshooting and is one method to shorten labor time.
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester on.
Select the following items from the DATA LIST.
TILT & TELESCO: Item
Measurement Item / Range (Display)
Normal Condition
Diagnostic Note
T&T Autoaway
Auto away and return function / ON or OFF
ON: Auto away and return function is allowed
OFF: Auto away and return function is restrained
-
Tilt Position
Current tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Position
Current telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Return Position
Memorized tilt return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Return Position
Memorized telescopic return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem1
Tilt & telescopic memory position 1 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 1
Tilt data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 1
Telescopic data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem2
Tilt & telescopic memory position 2 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 2
Tilt data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 2
Telescopic data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem3
Tilt & telescopic memory position 3 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 3
Tilt data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 3
Telescopic data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Up Limit
Uppermost tilt position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Up Limit Position
Uppermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Down Limit Pos
Lowermost tilt position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Down Limit Position
Lowermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Short Limit Pos
Shortest telescopic position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Telesco Short Limit Pos
Shortest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telsco Long Limit
Longest telescopic position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Telsco Long Limit Pos
Longest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Up Switch
Input state of tilt up by manual switch / ON or OFF
ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch
-
Tilt Up SW (MPX)
Communication state of tilt up input by manual switch / ON or OFF
ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch
-
Down Switch
Input state of tilt down by manual switch / ON or OFF
ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch
-
Tilt Down SW (MPX)
Communication state of tilt down input by manual switch / ON or OFF
ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch
-
Telesco Short Switch
Input state of telescopic short by manual switch / ON or OFF
ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch
-
Telesco Short SW (MPX)
Communication state of telescopic short input by manual switch / ON or OFF
ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch
-
Telesco Long Switch
Input state of telescopic long by manual switch / ON or OFF
ON: telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch
-
Telesco Long SW (MPX)
Communication state of telescopic long input by manual switch / ON or OFF
ON: Telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch
-
T&T Manual SW Data
Voltage data of manual switch / min.: 0 V, max.: 5 V
Neutral position: Below 0.2 V
Tilt up: 1.67 to 2.13 V
Tilt down: 0.54 to 0.74 V
Telescopic contract: 1.08 to 1.40 V
Telescopic extend: 2.22 to 2.77 V
-
Power Source Voltage
Voltage data of power supply / min.: 0 V, max.: 20 V
Actual power supply voltage
10 to 14 V
-
Freeze Speed Info
Vehicle speed data / 0 km/h (0 mph), max.: 255 km/h (158 mph)
Actual vehicle speed
-
IG Switch (MPX)
Communication state of engine switch / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
IG Switch
Input state of engine switch / ON or OFF
ON: Input signal is normal
OFF: Input signal is interrupted
-
Key Switch / MPX
Communication state of key switch confirmation signal / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
Key Code Confirm (MPX)
Communication state of key code confirmation signal / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
Receive from Body
Communication state of body ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Seat ECU
Communication state of seat ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Combi
Communication state of combination switch ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Meter
Communication state of combination meter signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Power ECU Info
Communication state of power source control ECU signal / OK or interruption
OK: Communication is normal
Interruption: Communication is interrupted
-
The Number of DTCs
Number of diagnosis code / min.: 0, max.: 255
Actual number of diagnosis code
-
COMBINATION SWITCH: Item
Measurement Item / Range (Display)
Normal Condition
Diagnostic Note
Telesc Short SW
Telesco SHORT switch status / OFF or ON
OFF: Telescopic short is not activated by manual switch
ON: Telescopic short is activated by manual switch
-
Telesc Long SW
Telesco LONG switch status / OFF or ON
OFF: Telescopic long is not activated by manual switch
ON: Telescopic long is activated by manual switch
-
Tilt Down SW
Tilt DOWN switch / OFF or ON
OFF: Tilt down is not activated by manual switch
ON: Tilt down is activated by manual switch
-
Tilt Up SW
Tilt UP switch / OFF or ON
OFF: Tilt up is not activated by manual switch
ON: Tilt up is activated by manual switch
-
| ACTIVE TEST |
- HINT:
- Performing the ACTIVE TEST is one of the methods to shorten labor time. It is possible to display the DATA LIST during the ACTIVE TEST.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester on.
Select the following items from the ACTIVE TEST.
TILT & TELESCO: Item
Vehicle Condition / Test Details
Diagnostic Note
TILT
Tilt operation / UP or DOWN
-
TELESCO
Telescopic operation / LONG or SHORT
-