FREEZE FRAME DATA
Troubleshooting
| FREEZE FRAME DATA |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and check the FREEZE FRAME DATA by following the prompts on the intelligent tester screen.
TILT & TELESCO: Item
Measurement Item / Range (Display)
Normal Condition
Diagnostic Note
T&T Autoaway
Auto away and return function / ON or OFF
ON: Auto away and return function is allowed
OFF: Auto away and return function is restrained
-
Tilt Position
Current tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Position
Current telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Return Position
Memorized tilt return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Return Position
Memorized telescopic return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem 1
Tilt & telescopic memory position 1 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 1
Tilt data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 1
Telescopic data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem 2
Tilt & telescopic memory position 2 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 2
Tilt data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 2
Telescopic data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
T&T Mem 3
Tilt & telescopic memory position 3 / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Memory Pos 3
Tilt data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Memory Pos 3
Telescopic data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Up Limit
Uppermost tilt position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Up Limit Position
Uppermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Tilt Down Limit Pos
Lowermost tilt position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Tilt Down Limit Position
Lowermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Short Limit Pos
Shortest telescopic position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Telesco Short Limit Pos
Shortest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Telesco Long Limit
Longest telescopic position / NOT MEM or MEM
NOT MEM: Position is not memorized
MEM: Position is memorized
-
Telesco Long Limit Pos
Longest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
7000 to 9000 H
(28672 to 36864 edge)
-
Up Switch
Input state of tilt up by manual switch / ON or OFF
ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch
-
Tilt Up SW (MPX)
Communication state of tilt up input by manual switch / ON or OFF
ON: Tilt up is activated by manual switch
OFF: Tilt up is not activated by manual switch
-
Down Switch
Input state of tilt down by manual switch / ON or OFF
ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch
-
Tilt Down SW (MPX)
Communication state of tilt down input by manual switch / ON or OFF
ON: Tilt down is activated by manual switch
OFF: Tilt down is not activated by manual switch
-
Telesco Short Switch
Input state of telescopic short by manual switch / ON or OFF
ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch
-
Telesco Short SW (MPX)
Communication state of telescopic short input by manual switch / ON or OFF
ON: Telescopic short is activated by manual switch
OFF: Telescopic short is not activated by manual switch
-
Telesco Long Switch
Input state of telescopic long by manual switch / ON or OFF
ON: telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch
-
Telesco Long SW (MPX)
Communication state of telescopic long input by manual switch / ON or OFF
ON: Telescopic long is activated by manual switch
OFF: Telescopic long is not activated by manual switch
-
T&T Manual SW Data
Voltage data of manual switch / min.: 0 V, max.: 5 V
Neutral position: Below 0.2 V
Tilt up: 1.67 to 2.13 V
Tilt down: 0.54 to 0.74 V
Telescopic contract: 1.08 to 1.40 V
Telescopic extend: 2.22 to 2.77 V
-
Power Source Voltage
Voltage data of power supply / min.: 0 V, max.: 20 V
Actual power supply voltage
10 to 14 V
-
Freeze Speed Info
Vehicle speed data / 0 km/h (0 mph), max.: 255 km/h (158 mph)
Actual vehicle speed
-
IG Switch (MPX)
Communication state of engine switch / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
IG Switch
Input state of engine switch / ON or OFF
ON: Input signal is normal
OFF: Input signal is interrupted
-
Key Switch / MPX
Communication state of key switch confirmation signal / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
Key Code Confirm (MPX)
Communication state of key code confirmation signal / ON or OFF
ON: Communication is normal
OFF: Communication is interrupted
-
Receive from Body
Communication state of body ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Seat ECU
Communication state of seat ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Combi
Communication state of combination switch ECU signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Receive from Meter
Communication state of combination meter signal / OK or Interruption
OK: Communication is normal Interruption: Communication is interrupted
-
Power ECU Info
Communication state of power source control ECU signal / OK or interruption
OK: Communication is normal
Interruption: Communication is interrupted
-