TERMINALS OF ECU
System information
| COMBINATION METER ASSEMBLY |


- Voltage:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J34-12 (IG+) - Body ground
Power supply
Engine switch OFF → ON (IG)
Below 1 V → 10 to 14 V
- Resistance:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J35-4 (P/SB) - Body ground
Passenger seat belt signal
The passenger seat is occupied, seat belt is fastened → unfastened
Below 1 Ω → 10 kΩ or higher
J34-1 (E2) - Body ground
Ground
Always
Below 1 Ω
| MULTI-MEDIA MODULE DISPLAY (WITH NAVIGATION SYSTEM) |


- Voltage:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J50-3 (IG+) - Body ground
Power supply
Engine switch OFF → ON (IG)
Below 1 V → 10 to 14 V
- Resistance:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J50-21 (PBEW) - Body ground
Passenger seat belt signal
The passenger seat is occupied seat belt is fastened → unfastened
Below 1 Ω → 10 kΩ or higher
| INTEGRATION CONTROL & PANEL (WITHOUT NAVIGATION SYSTEM) |


- Voltage:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J54-4 (IG+) - Body ground
Power supply
Engine switch OFF → ON (IG)
Below 1 V → 10 to 14 V
- Resistance:
Terminal No. (Symbols)
Terminal Description
Condition
Specified Condition
J54-13 (PBEW) - Body ground
Passenger seat belt signal
The passenger seat is occupied seat belt is fastened → unfastened
Below 1 Ω → 10 kΩ or higher