ON-VEHICLE INSPECTION
Inspection
| INSPECT STOP LIGHT CONTROL RELAY |
Remove the stop light control relay.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
Bellow 1 Ω
3 - 4
Below 1 Ω
(When battery voltage is not applied between terminals)
3 - 5
10 kΩ or higher
(When battery voltage is not applied between terminals)
3 - 4
10 kΩ or higher
(When battery voltage is applied between terminals 1 and 2)
3 - 5
Below 1 Ω
(When battery voltage is applied between terminals 1 and 2)