INSPECTION
Inspection
| REMOVE HEIGHT CONTROL SENSOR SUB-ASSEMBLY FRONT |
![]() ![]() |
Connect the 3 dry cell batteries (1.5 V) in series.
Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead from the battery to terminal 3.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
- Standard voltage:
Tester Connection
Condition
Specified Condition
A17-2 (SHFL) - A17-1 (SHG)
+45°
Approx. 4.5 V
A17-2 (SHFL) - A17-1 (SHG)
0°(normal)
Approx 2.5 V
A17-2 (SHFL) - A17-1 (SHG)
-45°
Approx 0.5 V
Remove the height control sensor.
| INSPECT HEIGHT CONTROL SENSOR SUB-ASSEMBLY REAR |
![]() ![]() |
Connect the 3 dry cell batteries (1.5 V) in series.
Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead from the battery to terminal 3.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
- Standard voltage:
Tester Connection
Condition
Specified Condition
Y2-2 (SHRL) - Y2-1 (SHG)
+45°
Approx. 4.5 V
Y2-2 (SHRL) - Y2-1 (SHG)
0°(normal)
Approx 2.5 V
Y2-2 (SHRL) - Y2-1 (SHG)
-45°
Approx 0.5 V