INSPECTION
Inspection
| INSPECT AMBIENT TEMPERATURE SENSOR |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
B5-1 - B5-2
10°C (50°F)
3.00 to 3.73 kΩ
B5-1 - B5-2
15°C (59°F)
2.45 to 2.88 kΩ
B5-1 - B5-2
20°C (68°F)
1.95 to 2.30 kΩ
B5-1 - B5-2
25°C (77°F)
1.60 to 1.80 kΩ
B5-1 - B5-2
30°C (86°F)
1.28 to 1.47 kΩ
B5-1 - B5-2
35°C (95°F)
1.00 to 1.22 kΩ
B5-1 - B5-2
40°C (104°F)
0.80 to 1.00 kΩ
B5-1 - B5-2
45°C (113°F)
0.65 to 0.85 kΩ
B5-1 - B5-2
50°C (122°F)
0.50 to 0.70 kΩ
B5-1 - B5-2
55°C (131°F)
0.44 to 0.60 kΩ
B5-1 - B5-2
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).