INSPECTION
Inspection
| INSPECT OVERHEAD JUNCTION BLOCK (PERSONAL LIGHT) |
Disconnect the R5 connector from the personal light.

Measure the resistance of the connector.
- Standard resistance:
Tester Connection
Condition
Specified Condition
R5-18 (GND3) - Body ground
Always
Below 1 Ω
Measure the voltage of the connector.
- Standard voltage:
Tester Connection
Condition
Specified Condition
R5-1 (+B) - Body ground
Always
10 to 14 V
Connect the (+) lead from the battery to terminal 1 and the (-) lead to terminal 18.

Check that the personal light comes on.
- OK:
Condition
Specified Condition
LH side personal light ON
LH side personal light comes ON
LH side personal light OFF
LH side personal light does not come ON
RH side personal light ON
RH side personal light comes ON
RH side personal light OFF
RH side personal light does not come ON