ON-VEHICLE INSPECTION
Inspection
| INSPECT EVAPORATOR TEMPERATURE SENSOR |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
e1-5 - e1-6
-10°C (14°F)
7.30 to 9.10 kΩ
e1-5 - e1-6
-5°C (23°F)
5.65 to 6.95 kΩ
e1-5 - e1-6
0°C (32°F)
4.40 to 5.35 kΩ
e1-5 - e1-6
5°C (41°F)
3.40 to 4.15 kΩ
e1-5 - e1-6
10°C (50°F)
2.70 to 3.25 kΩ
e1-5 - e1-6
15°C (59°F)
2.14 to 2.58 kΩ
e1-5 - e1-6
20°C (68°F)
1.71 to 2.05 kΩ
e1-5 - e1-6
25°C (77°F)
1.38 to 1.64 kΩ
e1-5 - e1-6
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).