Lexus IS250 · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications

Charging circuit without load
Standard amperage: 10 A or less
Standard voltage: 12.1 to 15.4 V
Charging circuit with load
Standard amperage: 30 A or more
Brush length
Standard: 10.5 mm (0.413 in.)
Minimum: 4.5 mm (0.177 in.)
Generator rotor assembly
Slip ring resistance: 1.5 to 1.9 kΩ at 20°C (68°F)
Standard slip ring diameter: 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum slip ring diameter: 14.0 mm (0.551 in.)
← TORQUE SPECIFICATIONSTORQUE SPECIFICATIONS →