АДСОРБЕР > ПРОВЕРКА

для подготовки Нажмите здесь



1. INSPECT CANISTER


    C149113E01
  1. Visually check the canister for cracks or damage.



    C149113E02
  1. Blow 4.4 kPa (45 gf/cm2, 0.63 psi) of compressed air into port A and check that air flows without resistance from port B and port C. If the result is not as specified, replace the charcoal canister.

  1. Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum does not decrease when port B is released. If the result is not as specified, replace the charcoal canister.



2. CLEAN FILTER IN CANISTER


A152195E01
  1. Clean the filter by blowing 4.4 kPa (45 gf/cm2, 0.63 psi) of compressed air into port A while holding port B closed.

    УКАЗАНИЕ:
    1. Do not attempt to wash the canister.
    2. No activated carbon should come out.