ГИДРАВЛИЧЕСКИЙ КЛАПАН ИЗМЕНЕНИЯ ФАЗ > СНЯТИЕ |
| 1. REMOVE COWL TOP VENTILATOR LOUVER RH |
![]() |
Remove the 6 clips and cowl top ventilator louver RH.
| 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 3. REMOVE V-BANK COVER SUB-ASSEMBLY |
![]() |
While using both hands, lift the rear side of the cover upwards to detach the 4 clips B. Slide the cover towards the front of the vehicle to detach the 2 clips labeled A, and remove the V-bank cover.
| 4. REMOVE AIR CLEANER INLET COVER |
![]() |
Remove the 5 clips A.
Lift up the air cleaner inlet cover to detach the 4 clips B, and remove the cover.
| 5. REMOVE NO. 1 AIR CLEANER INLET |
![]() |
Remove the 2 bolts.
![]() |
Hold the air cleaner inlet by the protrusions A and B, and detach the connections.
Rotate the No. 1 air cleaner inlet as shown in the illustration to detach the protrusion C.
Hold the air cleaner inlet by the protrusions D and E, and detach the connections.
Rotate the No. 1 air cleaner inlet as shown in the illustration to detach the protrusion F.
| 6. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Bank 1) |
![]() |
Disconnect the oil control valve connector.
Remove the bolt and oil control valve.
Remove the O-ring from the oil control valve.
| 7. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Bank 2) |
![]() |
Disconnect the oil control valve connector.
Remove the bolt and oil control valve.
Remove the O-ring from the oil control valve.