ПРИВОД КЛАПАНА УПРАВЛЕНИЯ ЗАБОРОМ ВОЗДУХА > ПРОВЕРКА

для подготовки Нажмите здесь



1. INSPECT INTAKE AIR CONTROL VALVE ACTUATOR


A149902E01
  1. When battery voltage is applied between terminals 1 and 2 of the connector, check the operation of the actuator shaft.

    Standard:
    Terminal Number (Battery Terminal)
    Specified Condition
    1 (battery terminal +) - 2 (battery terminal -)
    Actuator shaft rotates to left
    1 (battery terminal -) - 2 (battery terminal +)
    Actuator shaft rotates to right

    ПРИМЕЧАНИЕ:
    Apply battery voltage for 10 seconds or less each time the inspection is performed.