ЭЛЕКТРОДВИГАТЕЛЬ МЕХАНИЗМА ИЗМЕНЕНИЯ ФАЗ ГАЗОРАСПРЕДЕЛЕНИЯ > УСТАНОВКА |
| 1. INSTALL CAMSHAFT TIMING CONTROL MOTOR LH |
![]() |
Turn the camshaft timing gear assembly's eccentric shaft index slot in the counterclockwise direction by hand, and set it to the maximum retard angle position.
Install a new O-ring to the timing chain cover.
![]() |
Align the joint of the camshaft timing control motor and the keyway of the camshaft timing gear assembly, and install the motor with the 3 bolts.
![]() |
Connect the 2 camshaft timing control motor connectors and engine wire clamp.
| 2. INSTALL CAMSHAFT TIMING CONTROL MOTOR RH |
![]() |
Turn the camshaft timing gear assembly's eccentric shaft index slot in the counterclockwise direction by hand, and set it to the maximum retard angle position.
Install a new O-ring to the timing chain cover.
![]() |
Align the joint of the camshaft timing control motor and the keyway of the camshaft timing gear assembly, and install the motor with the 3 bolts.
![]() |
Install the engine wire bracket with the bolt.
Connect the 2 camshaft timing control motor connectors.
| 3. INSTALL INTAKE AIR CONNECTOR PIPE |
![]() |
Align the protrusion of the intake air resonator with the cutout of the bracket and insert the protrusion.
Install the intake air connector pipe with the 3 hose clamps.
![]() |
Connect the No. 1 ventilation hose and No. 2 ventilation hose to the intake air connector pipe.
| 4. INSTALL NO. 1 AIR CLEANER INLET |
![]() |
Align the holes with the connection areas labeled A, and attach the No. 1 air cleaner inlet.
![]() |
Install the No. 1 air cleaner inlet with the 2 bolts.
| 5. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY |
![]() |
Attach the 4 clips B.
Install the air cleaner inlet cover with the 5 clips A.
| 6. INSTALL V-BANK COVER SUB-ASSEMBLY |
![]() |
After sliding the cover from the vehicle front to the rear to attaching the 2 clips A, attach the 4 clips B and install the V bank cover.
| 7. REMOVE COWL TOP VENTILATOR LOUVER RH |
![]() |
Remove the 6 clips and cowl top ventilator louver RH.
| 8. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 10. INSTALL COWL TOP VENTILATOR LOUVER RH |
![]() |
Install the 6 clips and cowl top ventilator louver RH.
| 11. PERFORM INITIALIZATION |
Perform initialization (see page Нажмите здесь).