(a) Remove the front air mix servo motor.
(b) Connect positive (+) lead to terminal 3 (HMOT) and negative (-) lead to terminal 2 (MCOOL), and check the front air mix damper control servo motor.
OK:
The lever turns smoothly to warm side.
(c) Connect positive (+) lead to terminal 2 (MCOOL) and negative (-) lead to terminal 3 (HMOT), and check the front air mix damper control servo motor.
OK:
The lever turns smoothly to cool side.
|