(b) Inspect the pressure switch continuity (magnetic clutch control).
(1) Connect the positive (+) lead from the ohmmeter to terminal 4 and the negative (-) lead to terminal 1.
(2) Check the continuity between terminals when refrigerant pressure changes, as shown in the illustration.
If the continuity is not as specified, replace the pressure switch.
|