Last Modified: 4-30-2014 6.6 G Doc ID: RM0000019OU002X
Model Year: 2006 Model: LX470 Prod Date Range: [05/2005 -           ]
Title: DOOR LOCK: BACK DOOR LOCK: INSPECTION; 2006 MY LX470 [05/2005 -        ]

INSPECTION

1. INSPECT DOOR UNLOCK DETECTION SWITCH

(a) Check the continuity of the door unlock detection switch.

OK:

Tester Connection

Switch Condition

Specified Condition

1 - 4

OFF

(Door lock set to LOCK)

No continuity

1 - 4

ON

(Door lock set to UNLOCK

Continuity

If the result is not as specified, replace the door lock assembly.

2. INSPECT DOOR LOCK MOTOR OPERATION

(a) Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2, and check that the door lock link moves to the UNLOCK position.

(b) Reverse the polarity and check that the door lock link moves to the LOCK position.

If the operation is not as specified, replace the door lock assembly.

3. INSPECT PTC THERMISTOR OPERATION (Using an ammeter)

(a) Connect the battery negative (-) lead to terminal 2.

(b) Connect the ammeter negative (-) lead to terminal 3 and the ammeter positive (+) lead to the battery positive (+) terminal, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.

(c) Disconnect the leads from the terminals.

(d) Approximately 60 seconds later, connect the battery positive (+) lead to terminal 2 and the battery negative (-) lead to terminal 3, and check that the door lock moves to the LOCK position.

If the operation is not as specified, replace the door lock assembly.

4. INSPECT PTC THERMISTOR OPERATION (Using an ammeter with a current-measuring probe)

(a) Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2.

(b) Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.

(c) Disconnect the leads from the terminals.

(d) Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position.

If the operation is not as specified, replace the door lock assembly.