Title:
AIR CONDITIONING: BLOWER MOTOR CONTROL RELAY: ON-VEHICLE INSPECTION; 2006 MY LX470 [05/2005 - ]
ON-VEHICLE INSPECTION
1. CHECK BLOWER MOTOR CONTROL RELAY
(a) Connect the connector to the blower motor control relay and inspect the wire harness side connector from the backside as shown in the illustration.
Test condition:
Turn the ignition switch ON
Standard voltage:
Tester Connection
Condition
Specified Condition
1 - Ground
Always
Below 1 V
2 - Ground
Blower speed control switch at "LO" position
Approx. 3.5 V
Blower speed control switch at "M1" position
Approx. 2.2 V
3 - Ground
Operate blower motor
Battery positive voltage
Blower speed control switch at "OFF" position
No voltage
4 - 5
Blower speed control switch at "LO" position
Approx. 3.6 V
Blower speed control switch at "M2" position
Approx. 8.3 V
Blower speed control switch at "HI" position
Approx. 13.0 V
If the result is not as specified, replace the relay.