All functions do not operate
|
1. IG power source circuit
|
|
|
2. A/C amplifier
|
|
|
3. Navigation system
|
|
|
Air flow control: no blower operation
|
1. Heater main relay
|
|
|
2. Blower motor circuit
|
|
|
3. A/C amplifier
|
|
|
4. Blower motor control relay
|
|
|
Air flow control: no blower control
|
1. Blower motor circuit
|
|
|
2. A/C amplifier
|
|
|
3. Solar sensor circuit
|
|
|
4. Blower motor control relay
|
|
|
Air flow control: insufficient air flow
|
1. Blower motor circuit
|
|
|
2. Blower motor control relay
|
|
|
Temperature control: no cool air comes out
|
1. Refrigerant volume
|
|
|
2. Refrigeration system inspection with manifold gauge set
|
|
|
3. Compressor circuit
|
|
|
4. Pressure switch circuit
|
|
|
5. Front air mix damper position sensor circuit
|
|
|
6. Front air mix damper control servomotor circuit
|
|
|
7. Front room temperature sensor circuit
|
|
|
8. Ambient temperature sensor circuit
|
|
|
9. A/C amplifier
|
|
|
10. ECM
|
|
|
Temperature control: no warm air comes out
|
1. Front air mix damper position sensor circuit
|
|
|
2. Front air mix damper control servomotor circuit
|
|
|
3. Front room temperature sensor circuit
|
|
|
4. Ambient temperature sensor circuit
|
|
|
5. Front evaporator temperature sensor circuit
|
|
|
6. A/C amplifier
|
|
|
Temperature control: output air is warmer or cooler than the set temperature, or response is slow
|
1. Refrigerant volume
|
|
|
2. Refrigeration system inspection with manifold gauge set
|
|
|
3. Solar sensor circuit
|
|
|
4. Front room temperature sensor circuit
|
|
|
5. Ambient temperature sensor circuit
|
|
|
6. Front evaporator temperature sensor circuit
|
|
|
7. Front air mix damper position sensor circuit
|
|
|
8. Front air mix damper control servomotor circuit
|
|
|
9. Front air inlet damper position sensor circuit
|
|
|
10. Front air inlet damper control servomotor circuit
|
|
|
11. Condenser
|
|
|
12. Evaporator
|
|
|
13. Heater radiator
|
|
|
14. Expansion valve
|
|
|
15. A/C amplifier
|
|
|
16. ECM
|
|
|
Temperature control: no temperature control (only max, cool or max, warm)
|
1. Front room temperature sensor circuit
|
|
|
2. Ambient temperature sensor circuit
|
|
|
3. Front air mix damper position sensor circuit
|
|
|
4. Front air mix damper control servomotor circuit
|
|
|
5. A/C amplifier
|
|
|
No air inlet control
|
1. Front air inlet damper position sensor circuit
|
|
|
2. Front air inlet damper control servomotor circuit
|
|
|
3. A/C amplifier
|
|
|
No air flow control
|
1. Air outlet damper position sensor circuit
|
|
|
2. Air outlet damper control servomotor circuit
|
|
|
3. A/C amplifier
|
|
|
Engine idle up does not occur, or is continuous
|
1. Compressor circuit
|
|
|
2. ECM
|
|