Last Modified: 4-30-2014 6.6 N Doc ID: RM000001DU2001X
Model Year: 2006 Model: LX470 Prod Date Range: [05/2005 -           ]
Title: SUSPENSION CONTROL: PUMP ATTENUATOR: DISPOSAL; 2006 MY LX470 [05/2005 -        ]

DISPOSAL

1. DISPOSE OF PUMP ATTENUATOR

(a) Place the pump attenuator in a vise and saw a hole between "A" and "B" shown in the illustration using a saw to discharge the gas inside.

CAUTION:

  • As the gas is contained a metal bellows saw up to the metal bellows.
  • The gas discharging is colorless, odorless and harmless.
  • Saw a hole while covering the saw with a cloth because chips may fly up.