Last Modified: 7-3-2017 |
6.8:8.0.40 |
Doc ID: RM000000SWH01MX |
|
Model Year Start: 2007 |
Model: LX470 |
Prod Date Range: [08/2006 -
] |
|
Title: 2UZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0455,P0456; Evaporative Emission Control System Leak Detected (Gross Leak); 2007 MY LX470 [08/2006 - ] |
|
DTC
|
P0455
|
Evaporative Emission Control System Leak Detected (Gross Leak)
|
|
DTC
|
P0456
|
Evaporative Emission Control System Leak Detected (Very Small Leak)
|
DTC SUMMARY
|
DTC No.
|
Monitoring Item
|
Malfunction Detection Condition
|
Trouble Area
|
Detection Timing
|
Detection Logic
|
|
P0455
|
EVAP gross leak
|
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that EVAP system has large leak.
|
-
Fuel cap (loose)
-
Leakage from EVAP line (canister - fuel tank)
-
Leakage from EVAP line (purge VSV - canister)
-
Canister pump module
-
Leakage from fuel tank
-
Leakage from canister
|
While ignition switch OFF
|
2 trip
|
|
P0456
|
EVAP small leak
|
Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak check.
If stabilized pressure higher than second reference pressure, ECM determines that EVAP system has small leak.
|
-
Fuel cap (loose)
-
Leakage from EVAP line (canister - fuel tank)
-
Leakage from EVAP line (purge VSV - canister)
-
Canister pump module
-
Leakage from fuel tank
-
Leakage from canister
|
While ignition switch OFF
|
2 trip
|
DESCRIPTION
The circuit description can be found in the Evaporative Emission (EVAP) system
.
INSPECTION PROCEDURE
Refer to the EVAP system
.
MONITOR DESCRIPTION
5 hours* after the ignition switch is turned OFF, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.
HINT:
*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned OFF, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned OFF, the monitor check starts 2.5 hours later.
|
Sequence
|
Operation
|
Description
|
Duration
|
|
-
|
ECM activation
|
Activated by soak timer 5, 7 or 9.5 hours after ignition switch OFF.
|
-
|
|
A
|
Atmospheric pressure measurement
|
Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 76 kPa-a and 110 kPa-a (570 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
|
10 seconds
|
|
B
|
First reference pressure measurement
|
In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
|
60 seconds
|
|
C
|
EVAP system pressure measurement
|
Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
|
15 minutes*
|
|
D
|
Purge VSV monitor
|
Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normal.
|
10 seconds
|
|
E
|
Second reference pressure measurement
|
After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
|
60 seconds
|
|
F
|
Final check
|
Atmospheric pressure measured and then monitoring result recorded by ECM.
|
-
|
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
-
P0455: EVAP gross leak
In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second reference pressure x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leakage, illuminates the MIL and sets the DTC (2 trip detection logic).
-
P0456: EVAP very small leak
In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than the second reference pressure, the ECM determines that the EVAP system has a small leakage, illuminates the MIL and sets the DTC (2 trip detection logic).
MONITOR STRATEGY
|
Required Sensors/Components
|
Purge VSV and canister pump module
|
|
Frequency of Operation
|
Once per driving cycle
|
|
Duration
|
Within 15 minutes (varies with amount of fuel in tank)
|
|
MIL Operation
|
2 driving cycles
|
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
|
Enable conditions of EVAP key-OFF monitor
|
|
P043E (Reference orifice - low flow)
P043F (Reference orifice - high flow)
P0441 (Purge VSV - stuck open)
P0441 (Purge VSV - stuck close)
P0451 (Canister pressure sensor - noise)
P0455 (EVAP gross leak)
P0456 (EVAP small leak)
P2401 (Leak detection pump - stuck OFF)
P2402 (Leak detection pump - stuck ON)
P2419 (Vent valve - stuck ON)
P2420 (Vent valve - stuck OFF)
|
|
Atmospheric pressure
|
70 to 110 kPa-a (525 to 825 mmHg-a)
|
|
Battery voltage
|
10.5 V or higher
|
|
Vehicle speed
|
Less than 2.5 mph (4 km/h)
|
|
Ignition switch
|
OFF
|
|
Time after key off
|
5 or 7 or 9.5 hours
|
|
Canister pressure sensor malfunction (P0450, P0452, P0453)
|
Not detected
|
|
Purge VSV
|
Not operated by scan tool
|
|
Vent valve
|
Not operated by scan tool
|
|
Leak detection pump
|
Not operated by scan tool
|
|
Both of the following conditions 1 and 2 are met before key off
|
-
|
|
1. Duration that vehicle has been driven
|
5 minutes or more
|
|
2. EVAP purge operation
|
Performed
|
|
ECT
|
4.4 to 35°C (40 to 95°F)
|
|
IAT
|
4.4 to 35°C (40 to 95°F)
|
1. Key-off monitor sequence 1 to 8
1. Atmospheric pressure measurement
|
Next sequence is run if the following condition is met
|
-
|
|
Atmospheric pressure change
|
Less than 0.3 kPa-g (2.25 mmHg-g) in 1 second
|
2. First reference pressure measurement
|
Next sequence is run if the following conditions are met
|
-
|
|
EVAP pressure just after reference pressure measurement start
|
-1 kPa-g (-7.5 mmHg-g) or less
|
|
Reference pressure
|
-4.85 to -1.057 kPa-g (-36.4 to -7.93 mmHg-g)
|
|
Reference pressure
|
Saturated within 60 seconds
|
3. Vent valve stuck closed check
|
Next sequence is run if the following condition is met
|
-
|
|
EVAP pressure change after vent valve is ON
|
0.3 kPa-g (2.25 mmHg-g) or more
|
4. Vacuum introduction
|
Next sequence is run if the following condition is met
|
-
|
|
EVAP pressure
|
Saturated within 15 minutes
|
5. Purge VSV stuck closed check
|
Next sequence is run if the following condition is met
|
-
|
|
EVAP pressure change after purge valve is open
|
0.3 kPa-g (2.25 mmHg-g) or more
|
6. Second reference pressure measurement
|
Next sequence is run if the following conditions are met
|
-
|
|
EVAP pressure just after reference pressure measurement start
|
-1 kPa-g (-7.5 mmHg-g) or lower
|
|
Reference pressure
|
-4.85 to -1.057 kPa-g (-36.4 to -7.93 mmHg-g)
|
|
Reference pressure
|
Saturated within 60 seconds
|
|
Difference between first reference pressure and second reference pressure
|
Less than 0.7 kPa-g (5.25 mmHg-g)
|
7. Leak check
|
Next sequence is run if the following condition is met
|
-
|
|
EVAP pressure when vacuum introduction is complete
|
Second reference pressure or lower
|
8. Atmospheric pressure measurement
|
EVAP monitor is complete if the following condition is met
|
-
|
|
Atmospheric pressure difference between sequence 1 and 8
|
Within 0.3 kPa-g (2.25 mmHg-g)
|
TYPICAL MALFUNCTION THRESHOLDS
P0455: EVAP gross leak
|
FTP when vacuum introduction complete
|
Reference pressure x 0.2 or higher
|
P0456: EVAP small leak
|
FTP when vacuum introduction complete
|
Between "reference pressure" and "reference pressure x 0.2"
|
MONITOR RESULT
Refer to detailed information on MONITOR RESULT
.
|